Bruker Autoflex Speed MALDI TOF/TOF Mass Spectrometer
The instrument is mostly used for the determination of molecular weights of proteins, individual peptides, peptide mixtures, oligonucleotides, for the characterization of polymers and organometallics.
- Linear mass range at least up to 300 kDa.
- High mass resolution 10,000 –22,000 over a wide mass range in reflectron mode.
- LIFT technology for acquiring MS/MS spectra.
- Biotools software for protein/peptide identification
-
"Protease-Catalyzed L-Aspartate Oligomerization: SubstrateSelectivity and Computational Modeling", Yang F., Totsingan F., Dolan, Elliott; Khare, Sagar D.;Gross, Richard A. Omega,5(9),4403-4414, 2020.
-
"Sequence and Dispersity Are Determinants of Photodynamic Antibacterial Activity Exerted by Peptidomimetic Oligo(thiophene)s", Zhou, Zhe; Ergene, Cansu; Lee, Joshua Y.; Shirley, David J.; Carone, Benjamin R.; Caputo, Gregory A.; Palermo, Edmund F., ACS Applied Materials & Interfaces, 11,1896-1906, 2019
-
"Covalent binding of flavins to RnfG and RnfD in the Rnf complex from Vibrio cholera”. Backiel J.,Juárez O.,Zagorevski D.V.,Wang Z.,Nilges M.J.,Barquera B., Biochemistry.47(43):11273-84, 2008.
Equipment Rates & Fees
RPI Users | External Nonprofit | External Industry | External Industry Partners | |
---|---|---|---|---|
Standard | $54 | $89 | $151 | $136 |
Assisted | $108 | $178 | $355 | $320 |
Training | $80 | $132 | $263 | $237 |
RPI Users | External Nonprofit | External Industry | External Industry Partners | |
---|---|---|---|---|
Personnel Time | $73 | $120 | $240 | $216 |
Valid through July 31, 2025. Rates are hourly unless specified otherwise and are subject to change without further notice.
Required Acknowledgement and Authorship
Please acknowledge the CBIS Core Facilities in all publications and grant applications where our equipment and/or personnel have facilitated the work. These acknowledgements are very important because documenting our contributions helps to ensure that the resources of the Core Facilities are sustainable.
- Equipment: If you used Core Facility equipment, please note this in the Materials and Methods. e.g., Thermogravimetric analysis was carried out using a TA Instruments TGA-Q50 (Rensselaer CBIS Analytical Biochemistry Core Facility).
- Personnel: Please consider including CBIS personnel as co-authors on your publications when they have made a significant intellectual contribution to the research. Include CBIS Core Facility directors or staff as co-PI or co-investigators in grant applications when they provide a significant contribution to the grant proposal and scientific/intellectual leadership for the proposed work. Please follow these guidelines: ABRF Recommended Guidelines for Authorship on Manuscripts. Also, our Core Facility personnel always appreciate when they are mentioned in the Acknowledgements section of publications.
- Required Funding Authorization Form: Rensselaer researchers must fill out the CBIS Cores Authorization Form (PDF) to use the CBIS Core Facilities.